Datasheets

Every allowance we work to, written down.

These are the numbers the calculator uses. They are working allowances, confirmed with you in writing before anything is cut.

Deductions and tolerances
  • Floor gap5 mmUnder the glass, taken off the screen height
  • Hinge gap8 mmDoor edge to fixed panel or wall
  • Closing gap8 mmStrike side of the door
  • Channel deduction8 mmPer channelled edge
  • Max out of plumb10 mmBeyond this we size it with you
  • Max screen height2500 mmAbove this, call
Door limits
  • Minimum door width500 mm
  • Maximum door width1000 mm
  • Maximum door weight50 kg on two hinges
  • Third hingeDoors over 750 mm
Glass weight
  • 8 mm toughened low-iron20 kg/m²

    800×2000 mm = 32 kg

  • 10 mm toughened low-iron25 kg/m²

    800×2000 mm = 40 kg

Substrates and fixings

What's behind the tile matters.

Solid blockwork or brick

Standard plugs and screws in the kit. Drill on slow speed through tile, no hammer action.

Timber stud behind tile

Fix into the stud, not the board. Set out the channel to land on timber before the glass is cut.

Dot-and-dab plasterboard

Long-reach fixing pack required. Add it at order stage — it is not in the standard box.

Hardware spec sheets

Hinges, clamps and channel, drawn and dimensioned.

One sheet per part: sizes, cutout positions and glass thicknesses. Download what you need before you set out.

Download the full hardware catalogue
Glass processing

Cutouts go in before tempering.

Nothing can be drilled or notched once the glass is toughened. The hardware you choose decides the processing, so the kit is confirmed before the cutting list is released.

  • DH-GW90Two hinge notches in the door. See hinge sheet for positions.
  • DH-GG180Notches in both the panel and the door.
  • DA-KN30Ø12 mm knob hole in the door.
  • DC-GG90Ø16 mm hole in each panel.